Chemical Analysis Testing Laboratory: What to Check for Herbal Products
What a chemical analysis testing laboratory does for herbal supplements, which methods answer which question, and how to qualify a lab before you send samples.
Key Takeaway
What a chemical analysis testing laboratory does for herbal supplements, which methods answer which question, and how to qualify a lab before you send samples.
You have a botanical extract on the receiving dock, a supplier paperwork packet, and a decision to make: release it, hold it, or test it. Sending it to a chemical analysis testing laboratory sounds simple. In practice, “chemical analysis” covers very different questions, and a lab that is strong at one can be weak at another. This guide explains what chemical analysis can tell you about an herbal material, which techniques fit which question, and how to judge a laboratory before you rely on its report. Ayah Labs is the herbal testing satellite of Qalitex (powered by Qalitex), so the focus here stays on herbal and botanical materials.
What chemical analysis answers for a botanical
A single report rarely answers every question. It helps to separate the questions first:
- Identity: Is this the plant, and the plant part, you ordered?
- Composition: Which constituents are present, and at what levels?
- Adulteration: Has something been added or substituted to make the material look better than it is?
- Contaminants and release: Are there impurities, and does the finished dosage form release its active material properly?
The Botanical Safety Consortium’s chemical analysis group describes a “fit-for-purpose” approach. It used HPTLC and HPLC-UV-CAD-HRMS to support the identity of botanicals and to determine their phytochemical composition [1]. The same group notes that, depending on intended use, additional analysis such as volatile, nutritional or inorganic analysis can be done to characterize a botanical material more completely [1]. The practical lesson is that you choose the analysis to match the decision you need to make, rather than ordering a generic panel.
Identity: reading a fingerprint
For many botanicals, identity starts with a chromatographic fingerprint. In the consortium’s green tea example, one laboratory compared the test lot with its own green tea leaf extracts and looked at the pattern and retention factors (Rf) of the bands. It concluded that the lot was Camellia sinensis leaf extract [1]. Band intensities differed in places, which the authors attributed to natural variability of constituent concentration between extracts [1]. The missing band at the Rf of the caffeine standard (about 0.65) supported the conclusion that the lot was decaffeinated green tea extract [1].
A second laboratory used the same logic for a ginseng lot. It ran a variety of reference samples, and the lot’s constituent pattern matched Panax ginseng root references. Different patterns in other Panax varieties suggested the lot did not belong to those varieties [1]. The conclusion was Panax ginseng root extract [1].
Two points for your quality team:
- Identity by fingerprint depends on the reference samples the lab runs. A pattern with nothing to compare it against proves little.
- Some difference in intensity is normal. It does not by itself signal a problem, so the report should explain how the analyst judged a match.
Choosing the technique for the question
Different instruments answer different questions, and the literature is candid about their limits.
Mass spectrometry. MS identifies the amount and type of chemicals in a sample by measuring the mass-to-charge ratio and abundance of gas-phase ions, and it is useful for establishing the chemistry of botanical dietary supplements [2]. LC/MS and LC/MS/MS are described as extremely sensitive and highly specific for contaminants and illicit compounds, even at very low levels [2].
Targeted versus untargeted work. GC and LC coupled with MS suit targeted analysis better than general untargeted analysis, and untargeted results require comparison of full-scan spectra against preestablished libraries [2]. Ask a laboratory whether your question is targeted (“is this specific compound present?”) or untargeted (“what else is in here?”), because the confidence you can place in the answer differs.
Older, simpler methods. The same review points to a need for standardized methods that are more specific than TLC and LC-UV [2]. That does not make those methods useless. It means you should know what a given method can and cannot distinguish.
Multi-technique programs. The NIH and USDA collaborate on the Dietary Supplement Ingredient database, in which vitamins, minerals and botanicals were quantified using HPLC, LC/MS and ICP/MS [2]. Those samples were tested alongside matrix-matched NIST Standard Reference Materials with known values and uncertainties, to monitor laboratory performance [2]. Running a reference material in your own matrix is a good model for any lab’s quality system.
Adulteration: why the method matters
St. John’s wort shows how method choice interacts with fraud. The Botanical Adulterants Prevention Program reports that adulteration most often involves the undeclared addition of synthetic food dyes to the extract [5]. The purpose is to raise the apparent concentration of total hypericins when measured by spectrophotometric methods, which creates a false impression of a higher-quality ingredient [5].
Two details from that program are worth remembering. First, a BAPP technical director noted that such dye adulteration is readily detected by routine chemical analysis methods, while distinguishing Hypericum species based on chemical markers is really difficult [5]. Second, that same expert pointed out that knowing the value chain (where, how and by whom the herb is cultivated, collected and dried) is crucial for a reproducible composition [5]. A report alone does not replace supplier knowledge.
BAPP’s guidance document evaluates 67 published analytical methods for identifying authentic St. John’s wort and detecting adulteration, and it summarizes the advantages and disadvantages of each for quality control laboratories [5]. If you buy a botanical with a known adulteration history, ask whether your lab’s method was chosen with that history in mind.
Release performance is chemistry too
Content alone does not tell you whether a product will deliver its active material. The efficacy of a dietary supplement depends not only on the amount of active ingredient but also on the formulation’s design [2]. USP performance standards such as in vitro disintegration and dissolution tests are meant to detect problems with active ingredient release from dosage forms [2]. In the review’s description, disintegration testing shows how a tablet or capsule breaks apart under agitation within 30 min in specific solutions [2]. A product passes the dissolution test if, after 1 h, ≥ 75% of the marker compound is released into the simulated fluid [2]. If you make tablets or capsules, ask whether these tests belong in your program alongside identity and composition.
How to qualify the laboratory itself
A good method on paper means little if the work is done poorly. The HerbalGram review of contract laboratory qualification offers a practical framework [3].
Evaluate each service separately. Every laboratory has different areas of expertise, and with dietary supplement testing very little is routine and quality can vary significantly [3]. Do not assume a lab strong in one test is strong in another.
Ask who does the work. Many laboratories that offer numerous services subcontract some of them, and manufacturers need to know whether the work is done in-house or sent out [3].
Treat regulatory-sounding claims with care. The review states there is no such thing as an “FDA-approved” or “FDA-certified” laboratory [3]. An FDA inspection produces an inspection report, not a certification or accreditation [3]. If a lab you are considering has been inspected, request the report, when available, to see whether its operations are relevant to your analyses and whether any deficiencies were corrected [3]. “FDA-registered” involves no approval, certification, accreditation or inspection, so it says nothing about laboratory performance [3].
Audit on a regular basis. The review recommends site visits, paper audits and physical audits of a contract laboratory [3]. An audit should cover general and method-specific SOPs, staff education and training, method citations, date-stamped raw data and analytical testing reports [3]. It should also cover certificates of analysis for reference materials and purchase orders for reagents, columns and calibration standards [3]. A lab should be able to walk you through sample tracking, including sample and equipment logs, laboratory notebooks and the sample holding room [3]. Instrument logs should show usage and maintenance details [3].
Expect some limits. Because a laboratory protects client confidentiality, it may rightfully show auditors only the records for the testing being audited [3]. Refusal to show the relevant records is a different matter. The review says that without them, the manufacturer has no way to assure an FDA inspector of compliance during a GMP inspection [3].
Reading the report like a reviewer
Someone with the right background should review each analytical report. If you lack that person in-house, the review suggests contracting a qualified expert [3]. It also offers a blunt test: if a method citation looks like unintelligible gibberish, there is a fair chance that some obfuscation is occurring [3].
When you review a report or a published study on a botanical, check how completely the material is described. Authors of herbal trials are advised to document the source of specifications, the tests used and the results [4]. Details of identity, purity, composition and strength matter, as do geographical origin, whether the plant was cultivated or wild-collected, and whether voucher specimens were kept [4]. Where no chemical analysis was performed or reported, it can be difficult to tell whether the test article contained the herb at all [4]. The same logic applies to your own supplier data: a specification without a stated method and result is a claim, not evidence.
A short checklist before you send samples
- Write down the question first: identity, composition, adulteration, contaminants or release performance.
- Ask which method the lab will use, and whether it is targeted or untargeted.
- Ask whether reference materials or authentic reference samples are run with your sample.
- Confirm whether the testing is done in-house or subcontracted.
- Disregard “FDA-certified” claims, and ask for an inspection report where one exists.
- Plan a documented audit that covers SOPs, raw data, training and instrument logs.
- Have a qualified reviewer read every report, and question any method citation you cannot follow.
- Combine the lab result with what you know about the supplier’s value chain, especially for materials with a history of adulteration.
Results vary by matrix and by method, so confirm the approach with your regulatory affairs team before you finalize specifications.
Sources
- [1] Advancing Botanical Safety: A Strategy for Selecting, Sourcing, and Characterizing botanicals for developing Toxicological Tools - PMC (pmc.ncbi.nlm.nih.gov, accessed 2026-11-16)
- [2] Analytical Challenges and Metrological Approaches to Ensuring Dietary Supplement Quality: International Perspectives - PMC (pmc.ncbi.nlm.nih.gov, accessed 2026-11-16)
- [3] How to Qualify an Analytical Laboratory for Analysis of Herbal Dietary Ingredients and Avoid Using a “Dry Lab”: A review of issues related to using a contract analytical laboratory by industry, academ (herbalgram.org, accessed 2026-11-16)
- [4] Evaluating the Botanical Dietary Supplement Literature (herbalgram.org, accessed 2026-11-16)
- [5] Botanical Adulterants Prevention Program Publishes St. John’s Wort Laboratory Guidance Document (herbalgram.org, accessed 2026-11-16)
Written by Nour Abochama, VP Operations, Qalitex | Quality Consultant, Ayah Labs. Learn more about our team
Ship your sample to our Chicago facility — get a Qalitex CoA in 5–7 days. Contact us
Written by
Nour AbochamaVP Operations, Qalitex | Quality Consultant, Ayah Labs
Chemical engineer with 17+ years of experience in laboratory operations, quality assurance, and regulatory compliance. Expert in herbal and supplement testing, botanical identity, contract laboratory services, and ISO 17025 quality systems. Master's in Biomedical Engineering from Grenoble INP – Ense3. Former Director of Quality at American Testing Labs and Labofine. Executive Producer and co-host of the Nourify-Beautify Podcast.
Related Testing Services
Need contract testing?
Get a quote from Ayah Labs. 48-hour turnaround for chemistry tests. Signed CoA included.
Get a Testing Quote →